OPT FOR SECURITY AND PERFORMANCE

Improve the security and performance of your plant with alarm management, performance supervision, asset supervision, web-based data visualisation, optimisation, advanced control, and tuning with the new TaiJi tool.

Rethink your working methods and obtain immediate results thanks to our services, trainings, and consulting expertise. Manage changes intelligently with our proven solutions.

 certified service provider

January 2005

In this issue

puce About us
puce Classes and seminars
puce Trick for this month
puce To contact us

See our previous issues :
http://www.topcontrol.com/techinfo/news.php


About us

See us at Exfor 2005, Montréal February 8-10; our booth is 2010.

Michel Ruel (Top Control) and Jean-Guy Lagacé (Kruger Wayagamack) will present on Tuesday February 8, at 14 :00:

  • Case story : Using Performance Monitoring and Optimization Tools for a Paper Machine Start-up

See our 2005 calendar, Classes & Seminars :

See at : http://www.topcontrol.com/training/tcalendar.php



Classes & seminars

New-Orleans, February 8 Fat Tuesday, February 9-11
EX-501-3 - Detailed Loop Analysis with ExperTune
http://www.topcontrol.com/training/printable.php?id=10&type=cours

Bangkok, February 16-18
SE-100-3 - Seminar on modern control methods
http://www.topcontrol.com/training/printable.php?id=6&type=cours

Antofagasta, Chile, March 8-10
SE-100-3 - Seminar on modern control methods
http://www.topcontrol.com/training/printable.php?id=6&type=cours

Mexico, March 15-17
SE-100-3 - Seminar on modern control methods
http://www.topcontrol.com/training/printable.php?id=6&type=cours

Montreal, March 24-25
SE-120-2 - Seminar on performance assessment techniques using PlantTriage
http://www.topcontrol.com/training/printable.php?id=29&type=cours

New-York, March 27, Easter, March 29-31
SE-130-3 - Seminar on advanced tools in process control
http://www.topcontrol.com/training/printable.php?id=28&type=cours

Montreal, April 19-21
EX-501-3 - Detailed Loop Analysis with ExperTune
http://www.topcontrol.com/training/printable.php?id=13&type=cours


Kruger Wayagamack (paper mill Eastern Canada) case study:
Kruger Paper saves 1 million annually.
Fast and efficient startup of new paper machine using PlantTriage and Top Control support.

  • Startup 4 months ahead of schedule.
  • 2% increase in efficiency 1 year before projected best-case startup curves.
  • Resulting in an on-going savings of over 1 million dollars per year.
Watch the video: http://www.expertune.com/customersuccess.html


Trick for this month : Heat exchanger control

Tuning a temperature loop on a heat exchanger could be tricky.

For example, consider a simple liquid-liquid heat exchanger heating soup using hot water. The soup temperature controller manipulates the hot water flow to maintain temperature soup at set point.

  • This is a non-linear process (even with an equal percentage valve).
  • The same change in hot water flow will produce a larger temperature change at low soup flow.
  • The dynamic will also change with soup flow.
  • At low soup flow, dead time and time constant will increase.
  • Therefore, the tuning parameters should be adapted with the soup flow.

Feedforward measuring the soup flow and multiplying (Lead/Lag will be used) the output to the valve is also an interesting approach. Finally using a hot water flow controller in a cascade scheme will also improve performances.



To contact us

Comments, suggestions and requests are welcomed. Please e-mail us at: info@topcontrol.com

You are welcomed to visit our web site :http://www.topcontrol.com

puce

49 Bel-Air Street, Lévis, QC
G6V 6K9, Canada
Phone: (418) 834-2242
Fax: (418) 834-2651  

puce

4734 Sonseeahray Drive
Hubertus, WI 53033
Toll free: (877) 867-6473